ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 教員研究業績
  2. 薬品分析化学研究室
  3. 原著論文

Stepwise elusion method in micellar electrokinetic chromatography via sequential use of lithium perfluorooctadecyl sulfonate and lithium dodecyl sulfate

https://gifu-pu.repo.nii.ac.jp/records/14524
https://gifu-pu.repo.nii.ac.jp/records/14524
6d3282a8-7a95-4b2a-b869-4a673a46c228
Item type 研究室原著論文(1)
公開日 2022-03-06
タイトル
タイトル Stepwise elusion method in micellar electrokinetic chromatography via sequential use of lithium perfluorooctadecyl sulfonate and lithium dodecyl sulfate
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
抄録
値 An effective stepwise micellar electrokinetic chromatography (MEKC) elution method was developed using lithium perfluorooctadecyl sulfonate (LPFOS) and lithium dodecyl sulfate (LDS). The hydrogen-bonding property of LPFOS micelles differs from that of LDS micelles, which leads to remarkably different selectivity in the transfer of solutes to the micelles. The present stepwise method is performed by replacing the inlet reservoir of a first running solution containing LPFOS with that of a second running solution containing LDS during a single separation run in the absence of electroosmotic flow under acidic conditions, where LPFOS micelles work as carriers in first and then LDS micelles turn over. Effective separation of 15 nonionic aromatic compounds was controlled well by adjusting the time in the inlet reservoir, which could not be accomplished with systems using only LPFOS or only LDS, with significant changes in the elution order where necessary. Furthermore, separations with the present stepwise method were easily simulated, and the replacement time was optimized for 3.1 min from a 70.0 mM LPFOS solution to a 67.5 mM LDS solution with nearly complete separation within 15 min using the simulated parameters.
書誌情報 en : Journal of Chromatography A

巻 1358, p. 261-268, 発行日 2014
DOI
値 10.1016/j.chroma.2014.06.073
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 07:41:57.358967
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3